Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Rev. bras. cir. cardiovasc ; 36(5): 614-622, Sept.-Oct. 2021. tab, graf
Article in English | LILACS | ID: biblio-1351650

ABSTRACT

Abstract Introduction: Destructive aortic root endocarditis is associated with high mortality rates. The objective of this article was to characterize the clinical and microbiological profiles of these patients, especially concerning an already implanted aortic valve prosthesis. We also focused on prognostic factors. Methods: Eighty patients underwent aortic root replacement due to destructive endocarditis from 1999 to 2018 in our institution. We analyzed their pre, intra, and postoperative data, outcomes, and predictors of mortality. Results: Thirty-one patients had native valve endocarditis (NVE), eight patients had early-onset prosthetic valve endocarditis (PVE), and 41 patients had late-onset PVE. Streptococcus was found in 19.4% of NVE cases and no PVE case. Coagulase-negative Staphylococcus was responsible for 62.5% of the cases of early-onset PVE. Thirty-four (42.5%) patients had received inappropriate antibiotics before admission. No microorganism was associated with higher risk of mortality. Aortoventricular dehiscence was identified as an independent risk factor of mortality along with PVE, concomitant bypass surgery, and delayed diagnosis. The incidence of postoperative complications was similar in all three groups. Rates of long-term survival (P=0.044) and freedom from the composite endpoint (P=0.024) defined as death, stroke, aortic valve reinfection, and aortic valve reoperation were the lowest within the NVE group and the highest among the PVE patients. Conclusion: In endocarditis, prolonged diagnostics, inadequate antimicrobial treatment, and late surgery led to destructive local complications and worsened the prognosis. PVE is associated with higher mortality than NVE.


Subject(s)
Humans , Heart Valve Prosthesis/adverse effects , Prosthesis-Related Infections/surgery , Heart Valve Prosthesis Implantation/adverse effects , Endocarditis, Bacterial/surgery , Aortic Valve
2.
Rev. bras. cir. cardiovasc ; 35(4): 411-419, July-Aug. 2020. tab, graf
Article in English | LILACS, SES-SP | ID: biblio-1137311

ABSTRACT

Abstract Introduction: People with aortic/prosthetic valve endocarditis are a high-risk cohort of patients who present a challenge for all medically involved disciplines and who can be treated by various surgical techniques. Methods: We analyzed the results of treatment of root endocarditis with Medtronic Freestyle® in full-root technique over 19 years (1999-2018) and compared them against treatment with other tissue valves. Comparison was made with propensity score matching, using the nearest neighbor method. Various tests were performed as suited for adequate analyses. Results: Fifty-four patients in the Medtronic Freestyle group (FS group) were matched against 54 complex root endocarditis patients treated with other tissue valves (Tissue group). Hospital mortality was 9/54 (16.7%) in the FS group vs. 14/54 (25.6%) in the Tissue group (P=0.24). Cox regression performed for early results demonstrated coronary heart disease (P=0.004, odds ratio 2.3), among others, influencing early mortality. Recurrent infection was low (1.8% for FS and Tissue patients) and freedom from reoperation was 97.2% at a total of 367 patient-years of follow-up (median of 2.7 years). Conclusion: The stentless xenograft is a viable alternative for treatment of valve/root/prosthetic endocarditis, demonstrating a low rate of reinfection. The design of the bioroot allows for complex reconstructive procedures at the outflow tract and the annular level with at an acceptable operative risk. Endocarditis patients can be treated excluding infective tissue from the bloodstream, possibly with benefits, concerning bacteremia and recurrent infection. Furthermore, the use of the stentless bioroot offers varying treatment options in case of future valve degeneration.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Bioprosthesis/adverse effects , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Endocarditis, Bacterial/surgery , Aortic Valve/surgery , Prosthesis Design , Reoperation , Treatment Outcome , Propensity Score
3.
Rev. bras. cir. cardiovasc ; 35(3): 265-273, May-June 2020. tab, graf
Article in English | LILACS, SES-SP | ID: biblio-1137265

ABSTRACT

Abstract Objective: To analyze patients' preoperative characteristics, surgical data, postoperative courses, and short- and long-term outcomes after implantation of different full-root prostheses for destructive aortic valve endocarditis. Methods: Between 1999 and 2018, 80 patients underwent aortic root replacement due to infective endocarditis in our institution. We analyzed the abovementioned data with standard statistical methods. Results: The Freestyle stentless porcine prostheses were implanted in 53 (66.25%) patients, biological valve conduits in 13 (16.25%), aortic root homografts in nine (11.25%), and mechanical valve conduits in five (6.25%). There were no significant preoperative differences between the groups. The incidence of postoperative complications and intensive care unit length of stay did not differ significantly between the groups. The 30-day mortality rate was low among Freestyle patients (n=8, 15.1%) and high in the mechanical conduit cohort (n=3, 60%), though with borderline statistical significance (P=0.055). The best mean survival rates were observed after homograft (13.7 years) and stentless prosthesis (8.1 years) implantation, followed by biological (2.8 years) and mechanical (1.4 years) conduits (P=0.014). The incidence of reoperations was low in the mechanical conduit group (0) and stentless bioroot group (n=1, 1.9%), but two (15.4%) patients with biological conduits and three (33.3%) patients with homografts required reoperations in the investigated follow-up period (P=0.005). Conclusion: In patients with the destructive form of aortic valve endocarditis, homografts and stentless porcine xenografts offer better survival rates than stented valve conduits; however, the reoperation rate among patients who received homograft valves is high.


Subject(s)
Humans , Animals , Male , Female , Middle Aged , Aged , Bioprosthesis , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation , Endocarditis , Aortic Valve/surgery , Postoperative Complications/surgery , Reoperation , Swine , Follow-Up Studies
SELECTION OF CITATIONS
SEARCH DETAIL